首页 热点资讯 义务教育 高等教育 出国留学 考研考公
您的当前位置:首页正文

GSM话音测试报告(2012-3-9)

2020-11-03 来源:华拓网


安顺移动镇宁县城语音DT测试报告

安顺移动网络优化小组

2012年3月

1

(2012/3/6)

目 录

一、测试结果汇总 ····························································································································· 3 二、 电平、质量分布图 ····················································································································· 3

1.电平分布 ················································································································································· 3 2.话音质量 ················································································································································· 4

三、 案例分析 ····································································································································· 5

1.镇宁石柱湾路段切换延迟语音质量差 ································································································· 5 2.北街菜场附近占用工商局3小区信号语音质量差 ············································································· 5 3.三桥基站附近占用东大街1小区信号语音质量差 ············································································· 7 4.华原楼基站附近占用电力公司1800_2小区信号未接通一次 ···························································· 7

四、小结 ············································································································································· 8

2

一、 测试结果汇总(本周对镇宁县城进行整体DT测试,具

体指标如下:)

分公司 指标 网络类型 移动(GSM) 全程呼叫成功率(%) 96.97% 语音RxQuality质量 94.80% 紫云县 覆盖率(%) 99.62% 掉话率(%) 0.00% 接通率(%) 96.97% 二、 电平、质量分布图

1.电平分布

3

2.话音质量

4

三、 案例分析

1.镇宁石柱湾路段切换延迟语音质量差

问题分析:

在镇宁石柱湾路段车辆由东往西行驶测试中,MS占用镇宁电力公司3信号,接受电平-90dbm,其邻区镇宁石柱湾1电平-71dbm,未及时切换,电平拖延至低电平,引起语音质量差。 解决方案:

修改镇宁电力公司_3、镇宁电力公司1800_3向镇宁石柱湾1小区的切换参数,加强切换速度。

2.北街菜场附近占用工商局3小区信号语音质量差

5

问题分析:车辆在老贵黄公路由北往南行驶(北街菜场附近),MS占用镇宁工商局3信号,接受电平-64dbm,与邻区镇宁华原楼_1 BCCH同频干扰,引起语音质量极差(7级)。

解决方案:

修改工商局3小区(CI:557)BCCH:64->16,功率降低6db(美化天线)。

6

3.三桥基站附近占用东大街1小区信号语音质量差

问题分析:车辆东大街由东往西行驶测试中,MS占用东大街1小区信号,与移动大楼2小区TCH:35同频,引起语音质量差。

解决方案:修改移动大楼2小区TCH:35->32。

4.华原楼基站附近占用电力公司1800_2小区信号未接通一次

7

问题分析:华原楼由西往东行驶,占用电力公司1800_2小区信号(TCH:529),与镇宁水利局1800_3小区BCCH:528邻频,引起语音质量差,导致未接通一次。 解决方案:

修改镇宁水利局1800_3小区BCCH:528->543。

四、小结

本次对县城全面DT测试,总体测试指标良好,覆盖率99.62%,语音质量:94.80%,接通率96.97%,掉话率0%。

镇宁县城目前主要问题,个别基站覆盖过远,部分路段存在频率干扰,语音质量有一定影响,经对县城3个月的逐步优化调整,县城指标改善明显,已基本没有较大的网络问题,指标已比较稳定。

8

因篇幅问题不能全部显示,请点此查看更多更全内容